            Gold-life micropump development and production center

            Homepage
            Favorite

            | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

            Select micro-pump

            pressure unit conversion table

            GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

            Name and model

            Voltage

            (V)

            No-load Current

            (mA)

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            (mL/min)

            Weight

            (g)

            Pump Size

            Detailed Structure of the show

            reference Appearance

            GminiPA-1

            3.5

            30-50

            35

            -25

            800

            16

            162431

            >>here

            GminiPA-2

            3.5

            30-40

            35

            -20

            300

            16

            162431

            >>here

            Ibid

            pressure unit conversion table

            GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

            Name and model

            Voltage

            (V)

            No-load Current

            (mA)

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            (mL/min)

            Weight

            (g)

            Pump Size

            Installation instructions

            Detailed Structure of the show

            reference Appearance

            GminiPB-1

            3.5

            100

            35

            -25

            800

            28

            162441

            >>here

            GminiPB-2

            3.5

            100

            35

            -20

            300

            28

            162441

            >>here

            Ibid

            GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

            Name and model

            Voltage

            (V)

            No-load Current

            (mA)

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            (L/min)

            Weight

            (g)

            Pump Size

            Installation instructions

            Structure of the show

            reference Figure

            GMPA-1

            1.5-5

            test:4V

            40-100

            50

            20-30

            0.3-1.5

            35

            402336

            flow-load diagram

            voltage-flow chart

            Structure>>here

            GMPA-2

            2.0-5

            test:4V

            30-100

            50

            30-40

            0.5-2.0

            35

            402336

            Ibid

            Ibid

            GMPA-3

            3-6

            40-70

            50

            20-30

            0.5-1.5

            35

            402336

            Ibid

            Ibid

            GMPA-4

            3-6

            50-90

            50

            30-40

            0.5-1.8

            35

            402336

            Ibid

            Ibid

            GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

            Name and model

            Voltage

            (V)

            No-load Current

            (mA)

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            (L/min)

            Weight

            (g)

            Pump Size

            Installation instructions

            Structure of the show

            reference Figure

            GMPC-1/2/3

            6/9/12

            <200/120/90

            >100

            50-65

            2.5-3

            45

            502231

            Structure>>here

            flow-load diagram

            voltage-flow chart

            GMPC-4/5/6

            6/9/12

            <150/110/80

            >80

            50-55

            2.0-2.5

            45

            502231 ibid

            ibid

            GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

            Name and model

            Voltage

            (V)

            No-load Current

            (mA)

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            (L/min)

            Weight

            (g)

            Pump Size

            Installation instructions

            Structure of the show

            reference Figure

            GMPD-1/2/3

            6/12/24

            <230/130/80

            60-100

            60

            3-8

            82

            3544.556.5

            flow-load diagram

            voltage-flow chart

            Structure>>here

            GMPD-4/5/6

            6/12/24

            <200/100/60

            60-100

            50

            3-7

            82

            3544.556.5 ibid

            ibid

            Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

            GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

            Name and model

            Voltage

            (V)

            No-load Current

            mA

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GMPE-1/2

            12/24

            <180/90

            60

            50-55

            3-6

            149

            33543.572

            flow-load diagram

            voltage-flow chart

            Structure>>here

            GMPE-3/4/-

            12/24 -20-40 Custom 3L4L5L 149 3543.572

            Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

            GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

            Name and model

            Voltage

            (V)

            No-load Current

            A

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GMPF25-1/2

            12/24 0.6/.3 >100 -70 25 480 8656.5126

            Structure>>here

            GMPF15-3/4

            12/24 0.6/0.3 >60 -50 18 480 8656.5126

            Structure>>here

            GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

            Name and model

            Voltage

            (V)

            No-load Current

            A

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GMPG-1/2

            6-12/24

            <0.450

            100

            20-50

            36

            620

            8670126

            Structure>>here

            GMPG-3/4

            6-9/24

            <0.550

            100

            20-50

            36

            620

            8670126

            ibid

            GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

            Name and model

            Voltage

            (V)

            No-load Current

            A

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GDMPB-1/2

            6/12

            <0.25/0.135

            100

            series260

            -45-55

            series vacum

             -85

            single:22

            dual:2.8

            55

            244749

            flow-load diagram

            voltage-flow chart

            Structure>>here

            GDMPB-3/4

            6/12

            <0.25/0.135

            100

            series260

            50-65

            single:2.52

            dual:3.8

            55

            244749

            ibid

            GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

            Name and model

            Voltage

            (V)

            No-load Current

            A

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GDMPC-1/2

            12/24

            <0.135/0.08

            100

            series260

            -45-55

            series vacum

            -75

            single

            22L/min

            dual

            2.8L/min

            75

            244751

            flow-load diagram

            voltage-flow chart

            Structure>>here

            GDMPC-3/4

            12/24

            <0.135/0.08

            series

            260

            -50-65

            series vacum

            -80

            single:2.52

            dual:3.8

            5

            244751

            ibid

            GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

            Name and model

            Voltage

            (V)

            No-load Current

            mA

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GDMPD-1/2

            12/24

            <200

            /135

            100

            -40-50

            series vacum

            -75

            single:72

            dual:10

            107

            354855.5

            GDMPD-3/4

            12/24

            <240

            /135

            100

            -40-60

            series vacum

            -80

            single:82

            dual:11

            107

            354855.5

            GDMPD-5/6

            12/24

            <180

            /115

            100

            -35-45

            single:52

            dual:8

            107

            354855.5

            GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

            Name and model

            Voltage

            (V)

            No-load Current

            mA

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GDMPE-1/2

            12/24

            <180/100

            100

            -40-50

            series vacum

            -75

            single:62

            dual:10

            175

            354871.5

            flow-load diagram

            voltage-flow chart

            Structure>>here

            GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

            Name and model

            Voltage

            (V)

            No-load Current

            A

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GDMPF(40)-1/2

            12/24

            0.80

            100

            20-60

            single:282

            dual:40

            618

            1056.5126

            voltage-flow chart

            Structure>>here

            GDMPF(25)-3/4

            12/24

            0.70

            100

            20-60

            single:202,

            dual:25

            663

            1056.5126

            ibid

            GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

            Name and model

            Voltage

            (V)

            No-load Current

            A

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GDMPG(50)-1/2

            6-12/24

            <1.0

            60

            20-50

            single:352

            dual:50

            759

            11070126

            Structure>>here

            GDMPG(35)-3/4

            6-12/24

            <1.0

            -50-60

            20-50

            single:252

            dual:50

            759

            11070126

            Structure>>here

            GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

            Name and model

            Voltage

            (V)

            No-load Current

            A

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 4564.5124

            Structure>>here

            GFMPE-3/4

            12/24

            <0.67/0.35.67

            --

            45

            Four:3-15

            375 4564.5124
            Other Four:1-10 375 4564.5124

            HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

            Name and model

            Voltage

            (V)

            No-load Current

            mA

            Pressure

            (kPa)

            Vacum

            (kPa)

            Intake Flow

            L/min

            Weight(g)

            Pump Size

            Structure of the show

            reference Figure

            HLA-2

            --

            50mL and 100mL two tranches.

            Help

            Categories

             

                                       Return Home Page

            5544444